GD200A-S24 – VFD in single phase 220V to 3 phase 380V
GD200A-S24 series are specialized inverters for control applications of 380V 3-phase motors in places where only 1-phase 220V power grid is available.
Simple operation, durable, stable operation even in places where the power source is low voltage, flicker.
Inverter turns into 1 phase 220V to 380V 3 phase
                        For fastest support. Please Call 1800 6567 (Free)                    
                
                - Free delivery within Ha Noi, Ho Chi Minh, Can Tho
 - Free installation
 
| Brand: INVT | Warranty: 24 Months | 
| Specifications | Parameter | |
| Power input | Input voltage (V) | 1P, 160V ~ 245V, 7.5KW ~ 15KW | 
| Input frequency (Hz) | 47 ~ 63Hz | |
| Power output | Output voltage (V) | 3P, 0 ~ 380V | 
| Controller properties | Output frequency (Hz) | 0 ~ 400Hz | 
| Controller mode | Vectorzie V/F (SVPWM), Sensorless Vector (SVC), Torque control. | |
| Motor type | Asynchronous motor | |
| Speed range | 1:100 | |
| Speed control precision | ±0.2%, (SVC) | |
| Speed fluctuation | ±0.3%, (SVC) | |
| Torque response | ≤ 20 ms (SVC) | |
| Torque control error | 10 %, (SVC) | |
| Starting torque | 0.5 Hz 150% (SVC) | |
| Overload capacity | 150s for 250% of rated current | |
| Dynamic braking | integration brake | |
| Noise filter | Built-in C3, optional C2 | |
| Communication | Modbus RTU | |
| Terminal | Analog input | 04 inputs, can be set to NO or NC, integrated timer | 
| High speed pulse input | 01 high frequency pulse receiving input, PNP and NPN | |
| Analog Input | AI2: 0 ~10V/ 0~20mA, AI3: -10~10V. | |
| Digital Output | RO1A-NO, RO1B-NC, RO1C- Common | |
| Analog Output | AO1, AO2: 0/4~20mA or 0~10V | |
| opened collector Output | 1 ngõ ra opened collector. Tích hợp timer. | |
| High speed pulse output | output HDO (output ON – OFF or high frequency pulse output), Built-in timer | |
| Protection function | Protection in case of incidents: over current, high voltage, under voltage, over temperature, phase loss, phase difference, output line breakage, overload … | |
| Other functions | Self-voltage stabilization function (AVR) | Automatically stabilizes the output voltage when the supply voltage fluctuates abnormally | 
| Timer, counter function | Programmable timer and counter | |
| Torque compensation function | Increase the V / F control torque characteristic when the motor works at low speed. | |
| Pump pressure regulator function | Maintain water pressure in pump system. | |
| Brake control function | Dynamic brake, excitation brake | |
| Save Power function | Saving electricity when the engine is overloaded, improving the engine’s power factor | |
| Functions help the system to operate continuously | Maintains operation during transient power outages and wide operating voltage range suitable for flickering power locations. | |
| Function of inspection and supervision | Connect a computer to monitor the operation as well as parameter settings for the inverter using INVT studio V1.0 software | |
10.000+
Customers Nationwide
                                
                                    15+
Year Of Experiences
                                
                                    3000+
Warehouse Area Above 3000 m² Is Always Available Items That Help Customers Fast Project Progress
                                24h
24 Hours To Complete All Processes, Procedure Is Quick And Flexible
                                - Space vector control (SVPWM), Sensorless vector (SVC), torque control
 - Transforming source into 1 phase 220VAC to 3 phase 380VAC
 - Speed control accuracy to ± 0.2%, fast response <20ms
 - Keypad can be removed for remote monitoring and setting, copying parameters
 - 1-phase input voltage range, 200V (± 15%), suitable for power supply areas prone to low voltage, unstable
 - 30 functions for motor and inverter protection
 
				
            
                    
                        
                        
                        