{"id":193582,"date":"2020-09-25T15:54:21","date_gmt":"2020-09-25T08:54:21","guid":{"rendered":"https:\/\/dattech.com.vn\/nhung-tinh-nang-dac-biet-cua-bien-tan-trung-the-gd5000\/"},"modified":"2024-06-03T21:00:54","modified_gmt":"2024-06-03T14:00:54","slug":"nhung-tinh-nang-dac-biet-cua-bien-tan-trung-the-gd5000","status":"publish","type":"post","link":"https:\/\/dattech.com.vn\/en\/nhung-tinh-nang-dac-biet-cua-bien-tan-trung-the-gd5000\/","title":{"rendered":"Special Features of GD5000 Medium Voltage Inverter"},"content":{"rendered":"<p><a href=\"https:\/\/dattech.com.vn\/en\/p\/gd5000-series-medium-voltage-vector-inverter\/\">GD5000<\/a> is a new generation medium-voltage inverter produced by the INVT technology group, featuring many specialized features for medium-voltage motors. The GD5000 inverter applies a series power unit technique, combining 3-core DSP+PFGA+ARM technology for control systems and the most advanced SVPWM space vector control technology for highly accurate speed control results.<\/p>\n<p style=\"text-align: center;\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-5673\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/bien-tan-trung-the-gd5000-1166.png\" alt=\"\" width=\"600\" height=\"339\" title=\"\" srcset=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/bien-tan-trung-the-gd5000-1166.png 600w, https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/bien-tan-trung-the-gd5000-1166-300x170.png 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><em>GD5000 medium-voltage inverter<\/em><\/p>\n<p><strong>Notable Features of GD5000:<\/strong><\/p>\n<table style=\"border-collapse: collapse; width: 100%; border: 0px; height: 294px;\">\n<tbody>\n<tr style=\"height: 150px;\">\n<td style=\"width: 50%; border: 0px; height: 150px;\"><strong>1. Diverse control modes:<\/strong><\/p>\n<ul>\n<li><a href=\"https:\/\/dattech.com.vn\/cac-che-do-dieu-khien-trong-bien-tan\/\">V\/F Control<\/a><\/li>\n<li>Open-loop vector control<\/li>\n<li>Closed-loop vector control<\/li>\n<\/ul>\n<\/td>\n<td style=\"width: 50%; border: 0px; height: 150px;\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-5675\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-4165.png\" alt=\"\" width=\"161\" height=\"150\" title=\"\"><\/td>\n<\/tr>\n<tr style=\"height: 144px;\">\n<td style=\"width: 50%; border: 0px; height: 144px;\">\n<p><strong>2. Control of multiple motor types:<\/strong><\/p>\n<p>Can control both synchronous and asynchronous motors, easily switchable between the two by changing settings.<\/td>\n<td style=\"width: 50%; border: 0px; height: 144px;\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-5677\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-3165.png\" alt=\"\" width=\"200\" height=\"123\" title=\"\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>3. Four-quadrant control:<\/strong><\/p>\n<ul>\n<li>IGBT flow control and energy regeneration technology<\/li>\n<li>Large power regeneration capability.<\/li>\n<li>Independent flow control and inverter control.<\/li>\n<li>Each power unit independently locks phase.<\/li>\n<li>Strong adaptability to power grid fluctuations.<\/li>\n<\/ul>\n<table style=\"border-collapse: collapse; width: 100%; border: 0px; height: 1836px;\">\n<tbody>\n<tr style=\"height: 224px;\">\n<td style=\"width: 50%; border: 0px; height: 224px;\">\n<p><strong>4. LVRT \u2013 Low Voltage Ride Through operation:<\/strong><\/p>\n<p>&#8211; Strong capability to resist power grid fluctuations.<\/p>\n<ul>\n<li>Operates between 85%-110% of full load output<\/li>\n<li>Operates between 65%-85% in reduced load mode.<\/li>\n<li>Operates between 110%-120% in overload mode<\/li>\n<\/ul>\n<p>&#8211; Continues to run even during power grid loss for 1s to 5s.<\/td>\n<td style=\"width: 50%; border: 0px; height: 224px;\"><strong><img decoding=\"async\" class=\"aligncenter size-full wp-image-5681\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-7165.png\" alt=\"\" width=\"287\" height=\"200\" title=\"\"><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 200px;\">\n<td style=\"width: 50%; border: 0px; height: 200px;\">\n<p><strong>5. Speed tracking function:<\/strong><\/p>\n<p>Motor speed tracking function and recovery of running status in both dynamic and static modes.<\/td>\n<td style=\"width: 50%; border: 0px; height: 200px;\"><strong><img decoding=\"async\" class=\"aligncenter size-full wp-image-5683\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-8165.png\" alt=\"\" width=\"282\" height=\"200\" title=\"\"><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 232px;\">\n<td style=\"width: 50%; border: 0px; height: 232px;\">\n<p><strong>6. Bypass Unit Functionality:<\/strong><\/p>\n<p><strong>&#8211; Parallel Bypass:<\/strong><\/p>\n<ul>\n<li>In case of a unit failure, the bypass system activates a group of parallel units to maintain operational status.<\/li>\n<li>Applicable in conditions where operational conditions are favorable.<\/li>\n<li>Retains 60% of the remaining power capacity after bypassing two parallel unit groups.<\/li>\n<li style=\"list-style-type: none;\"><strong>\u00a0<\/strong><\/li>\n<\/ul>\n<\/td>\n<td style=\"width: 50%; border: 0px; height: 232px;\"><strong><img decoding=\"async\" class=\"aligncenter size-full wp-image-5685\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-9165.png\" alt=\"\" width=\"221\" height=\"200\" title=\"\"><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 200px;\">\n<td style=\"width: 50%; border: 0px; height: 200px;\"><strong>&#8211; Neutral Point Bypass:<\/strong><\/p>\n<ul>\n<li>When one unit fails, the bypass system redirects power around the faulty unit, maintaining the operation of other parallel units using advanced algorithms.<\/li>\n<li>Applicable in conditions where operational conditions are not optimal.<\/li>\n<li>Retains 87% of the remaining power capacity after bypassing two units per phase.<\/li>\n<\/ul>\n<\/td>\n<td style=\"width: 50%; border: 0px; height: 200px;\"><strong><img decoding=\"async\" class=\"aligncenter size-full wp-image-5687\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-10165.png\" alt=\"\" width=\"240\" height=\"200\" title=\"\"><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 200px;\">\n<td style=\"width: 50%; border: 0px; height: 200px;\"><strong>7. Low-frequency control function:<\/strong><\/p>\n<ul>\n<li>Advanced technology for recovering dead frequency zones.<\/li>\n<li>Low-frequency waveform close to sine wave.<\/li>\n<li>Optimization algorithm to eliminate low-frequency motor cogging.<\/li>\n<li style=\"list-style-type: none;\"><strong>\u00a0<\/strong><\/li>\n<\/ul>\n<\/td>\n<td style=\"width: 50%; border: 0px; height: 200px;\"><strong><img decoding=\"async\" class=\"aligncenter size-full wp-image-5689\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-11165.png\" alt=\"\" width=\"357\" height=\"200\" title=\"\" srcset=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-11165.png 357w, https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-11165-300x168.png 300w\" sizes=\"(max-width: 357px) 100vw, 357px\" \/><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 216px;\">\n<td style=\"width: 50%; border: 0px; height: 216px;\"><strong>8. Master-Slave control:<\/strong><\/p>\n<ul>\n<li>Master-slave control mode for up to 8 motors.<\/li>\n<li>Flexible connection in master-slave control.<\/li>\n<li>System continues to operate after inverter failure (even if master inverter fails).<\/li>\n<li>Faulty inverter can automatically re-enter the system after the fault is cleared.<\/li>\n<\/ul>\n<\/td>\n<td style=\"width: 50%; border: 0px; height: 216px;\"><strong><img decoding=\"async\" class=\"aligncenter size-full wp-image-5691\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-12165.png\" alt=\"\" width=\"314\" height=\"200\" title=\"\" srcset=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-12165.png 314w, https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-12165-300x191.png 300w\" sizes=\"(max-width: 314px) 100vw, 314px\" \/><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 264px;\">\n<td style=\"width: 50%; border: 0px; height: 264px;\">\n<p><strong>9. Outstanding Braking Performance:<\/strong><\/p>\n<p><strong>&#8211; Electromagnetic Braking Technology:<\/strong><\/p>\n<p>Suitable for abrupt stopping applications or applications where external rotational force impacts the load before starting.<\/p>\n<p><strong>&#8211; Dual-frequency Braking Technology:<\/strong><\/p>\n<p>Capable of generating powerful torque, significantly reducing stopping time, suitable for short braking periods.<\/td>\n<td style=\"width: 50%; border: 0px; height: 264px;\"><strong><img decoding=\"async\" class=\"aligncenter size-full wp-image-5693\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-13165.png\" alt=\"\" width=\"403\" height=\"200\" title=\"\" srcset=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-13165.png 403w, https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-13165-300x149.png 300w\" sizes=\"(max-width: 403px) 100vw, 403px\" \/><\/strong><\/td>\n<\/tr>\n<tr style=\"height: 300px;\">\n<td style=\"width: 50%; border: 0px; height: 300px;\"><strong>10. Flexible expansion design:<\/strong><\/p>\n<ul>\n<li>8 digital input channels.<\/li>\n<li>8 digital output channels.<\/li>\n<li>3 analog input channels.<\/li>\n<li>4 analog output channels.<\/li>\n<li>1 high-speed input channel.<\/li>\n<li>1 high-speed output channel.<\/li>\n<li>MODBUS communication standard, with 485 port support.<\/li>\n<li>PROFIBUS-DP support (optional).<\/li>\n<li>Ethernet support (optional).<\/li>\n<li style=\"list-style-type: none;\"><\/li>\n<\/ul>\n<\/td>\n<td style=\"width: 50%; border: 0px; height: 300px;\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-5695\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-15165.png\" alt=\"\" width=\"322\" height=\"300\" title=\"\" srcset=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-15165.png 322w, https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-15165-300x280.png 300w\" sizes=\"(max-width: 322px) 100vw, 322px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>11. Flexible switching:<\/strong><\/p>\n<ul>\n<li>Flexible switching between grid power and inverter power.<\/li>\n<li>Low current impact during switching.<\/li>\n<li style=\"list-style-type: none;\"><\/li>\n<\/ul>\n<table style=\"border-collapse: collapse; width: 100%; border: 0;\">\n<tbody>\n<tr>\n<td style=\"width: 50%; border: 0;\">\n<p><strong>12. User-Friendly Operation Interface:<\/strong><\/p>\n<p><strong>&#8211; Large Storage Memory:<\/strong><\/p>\n<p>Records the status of the unit, the inverter, error logs, and stores waveform charts.<\/p>\n<p><strong>&#8211; Error History Logging Function:<\/strong><\/p>\n<p>Automatically stores current, voltage, and other parameters when the inverter encounters an error during operation, storing the current waveform, accessible via PC software for accurate analysis of the cause of the malfunction.<\/td>\n<td style=\"width: 50%; border: 0;\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-5699\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-17165.png\" alt=\"\" width=\"457\" height=\"300\" title=\"\" srcset=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-17165.png 457w, https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-17165-300x197.png 300w\" sizes=\"(max-width: 457px) 100vw, 457px\" \/><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; border: 0;\"><strong>13. Other functions:<\/strong><\/p>\n<ul>\n<li>Support for password restriction function.<\/li>\n<li>Improved braking response.<\/li>\n<li>Strong overload capacity: 120% for 2 minutes, 150% for 5 seconds, 200% with instant protection.<\/li>\n<li>Full-load efficiency \u2265 96%.<\/li>\n<li>Input power factor at full load \u2265 0.97.<\/li>\n<li>Input and output current and voltage THD\uff1c2%.<\/li>\n<li style=\"list-style-type: none;\"><\/li>\n<\/ul>\n<\/td>\n<td style=\"width: 50%; border: 0;\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-5701\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-19165.png\" alt=\"\" width=\"368\" height=\"250\" title=\"\" srcset=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-19165.png 368w, https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/tinh-nang-gd5000-19165-300x204.png 300w\" sizes=\"(max-width: 368px) 100vw, 368px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Diverse Applications in Industry:<\/strong><\/p>\n<p>The GD5000 medium-voltage inverter is a versatile product suitable for various industrial applications. It is commonly used in heavy industries such as:<\/p>\n<table style=\"border-collapse: collapse; width: 100%; height: 342px; border: 0;\">\n<tbody>\n<tr style=\"height: 270px;\">\n<td style=\"width: 50%; height: 270px; border: 0;\">\n<p><strong>Thermal Power<\/strong><\/p>\n<p>Forced Draft Fans (FD), Induced Draft Fans (ID), Primary Fans, Secondary Fans, Water Pumps, Circulation Pumps, System Pumps<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-5703\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/nhiet-dien-2166.jpg\" alt=\"\" width=\"300\" height=\"150\" title=\"\"><\/td>\n<td style=\"width: 50%; height: 270px; border: 0;\">\n<p><strong>Mining Operations<\/strong><\/p>\n<p>Coal Conveyors, Hoists, Air Compressors, Air Blowers, Suction Pumps, Main Fans<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-5705\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/khai-thac-mo-2166.jpg\" alt=\"\" width=\"300\" height=\"150\" title=\"\"><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px; border: 0;\">\n<p><strong>Metallurgical Industry<\/strong><\/p>\n<p>High Furnace Blowers, Roaster Blowers, Circulating Pumps, Dust Extraction Fans, Rolling Mill Shafts<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-5707\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/luyen-kim-166.jpg\" alt=\"\" width=\"300\" height=\"150\" title=\"\"><\/td>\n<td style=\"width: 50%; height: 24px; border: 0;\">\n<p><strong>Petrochemical Industry<\/strong><\/p>\n<p>Main Pipeline Pumps, Oil Well Pumps, Intermediate Pumps<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-5709\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/cong-nghiep-hoa-dau-166.jpg\" alt=\"\" width=\"300\" height=\"150\" title=\"\"><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px; border: 0;\">\n<p><strong>Cement Industry:<\/strong><\/p>\n<p>Hot Air Fans, Dust Collection Fans, Ball Mills, Grinding Shafts<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-5711\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/xi-mang-166.jpg\" alt=\"\" width=\"300\" height=\"150\" title=\"\"><\/td>\n<td style=\"width: 50%; height: 24px; border: 0;\">\n<p><strong>Water Supply<\/strong><\/p>\n<p>Submersible Pumps, Clean Water Pumps, Wastewater Pumps, Oxygen Blowers<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-5713\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/cung-cap-nuoc-166.jpg\" alt=\"\" width=\"300\" height=\"150\" title=\"\"><\/td>\n<\/tr>\n<tr style=\"height: 24px;\">\n<td style=\"width: 50%; height: 24px; border: 0;\">\n<p><strong>Chemical Industry<\/strong><\/p>\n<p>Nitrogen Compressors, Gas Blowers, Circulation Pumps, CO2 Compressors<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-5715\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/cong-nghiep-hoa-hoc-166.jpg\" alt=\"\" width=\"300\" height=\"150\" title=\"\"><\/td>\n<td style=\"width: 50%; height: 24px; border: 0;\">\n<p><strong>Other Industries<\/strong><\/p>\n<p>Paper Industry, Pharmaceuticals, Fans, Pumps, Sugar Cane Industry: Cutting Knives, Press Shafts<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-5717\" src=\"https:\/\/dattech.com.vn\/wp-content\/uploads\/2020\/09\/cac-nganh-khac-166.jpg\" alt=\"\" width=\"300\" height=\"150\" title=\"\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Currently, DAT has successfully applied the GD5000 medium-voltage inverter to various clients, such as controlling coal hoist and conveyor systems at <a href=\"https:\/\/dattech.com.vn\/bien-tan-trung-the-gd5000-dieu-khien-bang-tai-than-tai-quang-ninh\/\">C\u00f4ng ty than Quang Hanh \u2013 Qu\u1ea3ng Ninh<\/a>, controlling the speed of Venturi fans \u2013 <a href=\"https:\/\/dattech.com.vn\/thep-hoa-phat-tin-tuong-su-dung-bien-tan-trung-the-gd5000-cua-invt-dieu-khien-quat-hut-bui-tinh-dien-4000-kva\/\">C\u00f4ng Ty Th\u00e9p H\u00f2a Ph\u00e1t<\/a>&#8230; DAT is the sole distributor in Vietnam to distribute <a href=\"https:\/\/dattech.com.vn\/en\/invt-vfd\/\" target=\"_blank\" rel=\"noopener noreferrer\">INVT inverters<\/a> GD5000 with the necessary qualifications to receive the genuine product warranty policy from INVT. In addition to ensuring product quality, DAT also researches specialized solutions to help optimize the efficiency of customer projects.<\/p>\n<div id=\"round\" style=\"background: #deebf7; padding: 10px; border-radius: 20px; border: 0px solid blue;\">\n<div style=\"text-align: center;\">\n<div><span style=\"color: #0092d7;\"><strong>Tranquility accompanies DAT&#8217;s ecosystem<\/strong><\/span><\/div>\n<p style=\"text-align: left;\">DAT Technology Co., Ltd. (DAT) proudly stands as a leading provider of products, solutions, and services in the Vietnamese market for variable frequency drives, automation, elevator control, and solar energy.<\/p>\n<ul style=\"text-align: left;\">\n<li>With over <span style=\"color: #f7931d;\"><strong>14 years of experience<\/strong><\/span> in developing automation solutions, DAT has sold 500,000 products to over 7,000 customers nationwide.<\/li>\n<li>With a team of <span style=\"color: #f7931d;\"><strong>over 350<\/strong><\/span> talented and experienced engineers<\/li>\n<li>DAT ensures prompt delivery and cost-saving technical support through a large inventory of variable frequency drives up to<span style=\"color: #f7931d;\"><strong> 1000kW<\/strong><\/span> and a nationwide technical service network available 24\/7.<\/li>\n<li>The flexible process of<span style=\"color: #f7931d;\"><strong> &#8220;Replace first, formalities later&#8221;<\/strong><\/span>.<\/li>\n<li>DAT is a comprehensive strategic partner with the technology conglomerate INVT, collaborating from research and testing to product and solution introduction to the market.<\/li>\n<li>By deeply understanding and mastering technology, DAT optimizes processes, solutions, and services.<\/li>\n<li>DAT provides technical training programs, technology understanding, and machinery upgrade consultancy for customers.<\/li>\n<\/ul>\n<p style=\"text-align: left;\"><em>For more detailed information, please visit <a href=\"https:\/\/dattech.com.vn\/en\/\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"color: #0092d7;\"><strong>www.dattech.com.vn<\/strong><\/span><\/a> and call the toll-free <strong>HOTLINE <a href=\"tel:18006567\"><span style=\"color: #ff0000;\">1800 6567<\/span><\/a><\/strong>\u00a0<\/em><\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>GD5000 is a new generation medium-voltage inverter produced by the INVT technology group, featuring many specialized features for medium-voltage motors. The GD5000 inverter applies a series power unit technique, combining 3-core DSP+PFGA+ARM technology for control systems and the most advanced SVPWM space vector control technology for highly accurate speed control results. GD5000 medium-voltage inverter Notable &#8230; <a title=\"Special Features of GD5000 Medium Voltage Inverter\" class=\"read-more\" href=\"https:\/\/dattech.com.vn\/en\/nhung-tinh-nang-dac-biet-cua-bien-tan-trung-the-gd5000\/\">Read more<span class=\"screen-reader-text\">Special Features of GD5000 Medium Voltage Inverter<\/span><\/a><\/p>\n","protected":false},"author":2,"featured_media":5720,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[2],"tags":[],"class_list":["post-193582","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tech-news","newspapers-tin-cong-nghe-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/dattech.com.vn\/en\/wp-json\/wp\/v2\/posts\/193582","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dattech.com.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dattech.com.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dattech.com.vn\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/dattech.com.vn\/en\/wp-json\/wp\/v2\/comments?post=193582"}],"version-history":[{"count":0,"href":"https:\/\/dattech.com.vn\/en\/wp-json\/wp\/v2\/posts\/193582\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dattech.com.vn\/en\/wp-json\/wp\/v2\/media\/5720"}],"wp:attachment":[{"href":"https:\/\/dattech.com.vn\/en\/wp-json\/wp\/v2\/media?parent=193582"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dattech.com.vn\/en\/wp-json\/wp\/v2\/categories?post=193582"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dattech.com.vn\/en\/wp-json\/wp\/v2\/tags?post=193582"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}